Polyscience P35N5A101B IP-35 Immersion Probe Cooler, 1.875″ Rigid Coil Probe, -35 to +40C, 120V, 60Hz
Working Temperature Range
-35°C to +40°C
Probe
1.875″ Rigid Coil
Cooling Capacity @ -20°C(W) (60Hz)
1004W
Features
- Continuous cooling to temperatures as low as -35°C
- Designed to run at maximum cooling
- An economical alternative to dry ice or liquid nitrogen
- Excellent for trapping applications, freeze drying, and rapidly cooling small volumes of liquids
*Similar Model DepictedPolyScience Low Temperature Coolers enhance and simplify low-temperature laboratory work, providing rapid, low-cost cooling of liquids to temperatures as low as -100C. Typical applications include the cooling of exothermic reactions, vapor and solvent trapping, and impact testing. They’re also ideal for extending the temperature range of non-refrigerated circulators to below ambient and boosting the cooling capacity of refrigerated circulators.
Enhance and simplify your low-temperature laboratory work with a PolyScience Low Temperature Cooler. Available in both immersion probe and flow-through styles, they provide rapid, low-cost cooling of liquids to temperatures as low as -100C. Typical applications include the cooling of exothermic reactions, freeze point determinations, freeze drying, impact testing, lyphilization, and vapor and solvent trapping.
INCLUDED:
The Polyscience P35N5A101B IP-35 Immersion Probe Cooler, -35°C to 40°C, 1004W; 120Vincludes:
- Power Cord
- Operator’s Guide
- Manufacturer’s Documentation
- 2 Year Manufacturer’s Warranty
Polyscience P35N5A101B IP-35 Immersion Probe Cooler, 1.875″ Rigid Coil Probe, -35 to +40C, 120V, 60Hz Specifications
| Description | Immersion Probe-35, 1.875″ Rigid Coil |
| Working Temperature Range C | -35° to +40° |
| Temperature Control (C) | Fixed at -35° |
| Cooling Capacity @ -30C (60Hz) | 106W |
| Cooling Capacity @ -20C (60Hz) | 152W |
| Cooling Capacity @ -10C (60Hz) | 253W |
| Cooling Capacity @ 0C (60Hz) | 421W |
| Cooling Capacity @ +10C (60Hz) | 703W |
| Cooling Capacity @ +20C (60Hz) | 1004W |
| Cooling Capacity @ +30C (60Hz) | 1205W |
| Cooling Capacity @ +40C (60Hz) | 1326W |
| Electrical Requirements (VAC/Hz/Ph/A) | 120/60/1/5 |
Comparison of Models
|
Specification |
Polyscience P10N4A101B IP-100 |
Polyscience P10N6A101B IP-100 |
Polyscience P10N8A101B IP-100 |
Polyscience P35N5A101B IP-35 |
Polyscience P40N7A101B IP-35 |
Polyscience P60N2A101B IP-60 |
Polyscience P60NNA101B IP-60 |
Polyscience P80NHA101B IP-80 |
Polyscience P80NMA101B IP-80 |
|
Immersion Probe-100, Rigid Cold Finger |
Immersion Probe-100, 3″ Rigid Coil |
Immersion Probe-100, Rigid Cold Finger |
Immersion Probe-35, 1.875″ Rigid Coil |
Immersion Probe-35, 3″ Rigid Coil |
Immersion Probe-60, 1.5″ Rigid Coil |
Immersion Probe-60, 1.5″ Rigid Coil with 180° bend |
Immersion Probe-80, 1.5″ Rigid Coil |
Immersion Probe-80, 1.75″ Rigid Coil with 180° bend |
|
|
Working Temperature Range (°C) |
-100° to -60° |
-100° to -60° |
-100° to -60° |
-35° to +40° |
-35° to +40° |
-60° to -20° |
-60° to -20° |
-80° to -40° |
-80° to -40° |
|
Temperature Control (°C) |
Fixed at -100°C |
Fixed at -100°C |
Fixed at -100°C |
Fixed at -35°C |
Fixed at -35°C |
Fixed at -60°C |
Fixed at -60°C |
Fixed at -80°C |
Fixed at -80°C |